LBSA 24V 104Ah 2.66KWh LIFePO4 Lithium Ion Battery
LBSA 24V 104Ah 2.66KWh LIFePO4 Lithium Ion Battery
LBSA 24V 104Ah 2.66KWh LIFePO4 Lithium Ion Battery
LBSA 24V 104Ah 2.66KWh LIFePO4 Lithium Ion Battery
LBSA 24V 104Ah 2.66KWh LIFePO4 Lithium Ion Battery
  • On sale!
  • -5%
  • New
LBSA 24V 104Ah 2.66KWh LIFePO4 Lithium Ion Battery
LBSA 24V 104Ah 2.66KWh LIFePO4 Lithium Ion Battery
LBSA 24V 104Ah 2.66KWh LIFePO4 Lithium Ion Battery
LBSA 24V 104Ah 2.66KWh LIFePO4 Lithium Ion Battery
LBSA 24V 104Ah 2.66KWh LIFePO4 Lithium Ion Battery

LBSA 25.6V 104Ah 2.66KWh LIFePO4 Lithium Ion Battery 24V 1C

R13,349.00 R12,681.55
Tax included
In Stock at Create Energy

Lithium Batteries South Africa 24V 104Ah 2.66KWh LIFePO4 Lithium Ion Battery

24V, 104Ah 2.66kWh

10 Year or 4500 cycles (9000 Cycles on BMS display) Warranty

CAN Bus Comms: Victron, Growatt, Sunsynk, DEYE

Description

2.5KW Max Continuous Load
Cycle life

10 Year or 4500 cycles (9000 Cycles on BMS display) Warranty

Applicable for all batteries purchased after 2022/11/21

Details:

CAN Bus Comms: Victron, Growatt, Sunsynk, DEYE
Bulk + Absorption: 28v
Float : 28v
Low Voltage Cut Off: 22v
Maximum continuous Charge/Discharge For Single Unit: 100A (Recommended 75A)
Charge for Parallel units: (100A*"Units In parallel") / 2
Discharge for Parallel units: 100A * "Units in parallel

Display Definitions:
OV - Warn: high pressure alarm
OV - Prot: over-voltage protection
UV - Warn: low pressure alarm
UV - Prot: under-voltage protection
OT-Warn:High temperature alarm
OT-Prot:Over temperature protection
UT - Warn: low temperature alarm
UT - Prot: low temperature
OC - Warn: over-current alarm
OC - Prot: over-current protection
CAPA - Warn: remaining capacity of the alarm
OFF - USE: failure alarm
SCP:Short circuit protection

LBSA Built Units Manufacturer's Warranty

10 Year or 4500 cycles

(9000 Cycles on BMS display) Warranty Applicable for all batteries purchased from 2022/11/21

  • This warranty is valid only on LBSA Built units where applicable.
  • Any physical damage to the battery box, display, terminals, buttons and or any other part of the battery automatically voids the warranty.
  • Removal or damage of Warranty sticker voids the warranty.
  • Any sign or water or liquid damage voids the warranty.
  • Damage caused during courier is not covered under this warranty.
  • Damage due to improper installation: loose terminal connections, under-sized cabling, incorrect connections (Series and parallel) for desired voltage and AH requirements or reverse polarity connections.
  • All installations should comply to all relevant SANS regulations and should have a valid COC issued. (Surge protection on both PV and AC input is essential)
  • Damage due to over charge or over discharge voids warranty.
  • When utilizing CANbus communication only PIN 4 and PIN 5 on the battery side can be used. Using pins other than pin 4 and 5 could cause damage to the BMS and will void the warranty.
  • Batteries that have been opened, modified or tampered with automatically voids this warranty.
  • When lodging a warranty claim the unit needs to be brought in to LBSA offices at 54 Mimetes rd, Denver, Johannesburg, 2011 OR Units 9 & 10, 1 Michigan st, Bonquinar Industrial Area, Matroosfontein, Cape Town, 7490. LBSA will not be liable for shipping fees for a unit that is older than 3 Months or if the unit was collected by the customer or courier arrange by the customer and not through LBSA.
  • Low voltage batteries or batteries with single cells that have inconsistent voltages can be returned to LBSA for balancing of the cells.
  • Removal of any LBSA logo or writing on any item automatically voids the warranty.
  • Any changes made to the battery BMS parameters will result in immediate termination of your warranty.

WARNING

  • Do not touch the cells with wet hands.
  • Do not crush, drop or puncture the cells.
  • Always dispose of the cells according to local safety regulations.
  • Do not reverse the polarity when installing.
  • Do not short circuit the terminals, remove all jewellery items that could cause a short circuit before installation and handling
  • Disconnect battery from power or loads, and then power off battery before installation and maintenance.
  • Continued operation of a damaged battery pack can result in damage or injury.
  • Ensure that all products, including but not limited to LiFePo4 Cells, DIY kits, BMS’s, Circuit breakers, Terminals, Busbars etc. are well isolated and secured when installing.
  • Any loophole, exception or situation not explained or listed in the above warranty will be evaluated and an outcome or solution will be determined with sole discretion by LBSA with fair consideration.
Product Details
LBSA25.6V104Ah2.66kWh

Data sheet

Nominal Capacity104Ah, 2.66kWh / 2660Wh
Nominal Voltage25.6VDC (24VDC)
Battery TypeLiFePO4
Reviews(0)

Reviews

No customer reviews for the moment.

You need to be logged in or create an account to give your appreciation of a review.

CREATE ENERGY

Compare0My Wishlist0

Your cart

There are no more items in your cart

Sign in