Victron Quattro II 48/5000/70-100/100-S 230V VE.Bus
Victron Quattro II 48/5000/70-100/100-S 230V VE.Bus
Victron Quattro II 48/5000/70-100/100-S 230V VE.Bus
Victron Quattro II 48/5000/70-100/100-S 230V VE.Bus
  • On sale!
  • -33.01%
  • New
Victron Quattro II 48/5000/70-100/100-S 230V VE.Bus
Victron Quattro II 48/5000/70-100/100-S 230V VE.Bus
Victron Quattro II 48/5000/70-100/100-S 230V VE.Bus
Victron Quattro II 48/5000/70-100/100-S 230V VE.Bus

Victron Quattro II 48/5000/70-50 230V VE.Bus 48V 5kVA Inverter / Charger

R31,973.45 R21,419.01
Tax included

Victron Quattro II 48/5000/70-50 230V VE.Bus

Multifunctional

Pure Sine Wave Inverter / Charger

2 AC Inputs and Auto connects to active source

adaptive charging, hybrid PowerAssist technology, plus multiple system integration features such as 3ph or 1ph / parallel operation.

5000VA / 4000W @ 25°C

48VDC, 70A Charger, Lithium Ion battery compatible

230VAC

Description

Victron Quattro II 48/5000/70-50 230V VE.Bus

5000VA / 4000W @ 25°C

48VDC, 70A Charger

230VAC

Please contact us for quantity discounts

Email: info@createenergy.co.za or telephone: +(27) 11 888 0410

 Two AC inputs & two AC Outputs

The Quattro-II can be connected to two independent AC sources, for example shore-side power and a generator, or two generators. The Quattro-II will automatically connect to the active source. The main output has no-break functionality. In the event of a grid failure, or shore or generator power being disconnected, the Quattro-II takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on one of the inputs of the Quattro-II. Loads that should not discharge the battery, such as air-conditioning or a water heater can be connected to this output.

  Unique PowerAssist feature

The Quattro-II will prevent overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shore side supply with power taken from the battery.

 Virtually unlimited power thanks to parallel operation

Up to 6 Quattros-II can operate in parallel to achieve higher power output. Three phase or split phase operation is also possible. 

Remote Monitoring and Control

Monitor and control your Quattro II and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, via the required Color Control GX or Venus GX, from adjusting your Quattro to setting a Geofence for hire vehicles and more...

Three phase capability

Three Quattro II units can be configured for three phase output. But that’s not all: up to 6 sets of three units can be parallel
connected to provide 144kW / 180kVA inverter power and more than 2500A charging capacity.

PowerControl – Dealing with limited generator, shore side or grid power

The Quattro II is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side
supply (16A per 5kVA Quattro at 230VAC). A current limit can be set on each AC input. The Quattro will then take
account of other AC loads and use whatever is spare for charging, thus preventing the generator or mains supply from
being overloaded.

PowerAssist – Boosting shore or generator power

This feature takes the principle of PowerControl to a further dimension allowing the Quattro to supplement the
capacity of the alternative source. Where peak power is so often required only for a limited period, the Quattro will
make sure that insufficient mains or generator power is immediately compensated for by power from the battery. When
the load reduces, the spare power is used to recharge the battery.

Solar energy: AC power available even during a grid failure

The Quattro II can be used in off grid as well as grid connected PV and other alternative energy systems.
Loss of mains detection software is available.

System configuring

  • In case of a stand-alone application, if settings have to be changed, this can be done in a matter of minutes with
    a DIP switch setting procedure.
  • Parallel and three phase applications can be configured with VE.Bus Quick Configure and VE.Bus System
    Configurator software.
  • Off grid, grid interactive and self-consumption applications, involving grid-tie inverters and/or MPPT Solar
    Chargers can be configured with Assistants (dedicated software for specific applications).

On-site Monitoring and control

Several options are available: Battery Monitor, Multi Control Panel, Color Control GX or other GX devices, smartphone or
tablet (Bluetooth Smart), laptop or computer (USB or RS232).

Remote Monitoring and control

Color Control GX or other GX devices.
Data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.

Remote configuring

When connected to the Ethernet, systems with a Color Control GX or other GX device can be accessed and settings can