CET3300 Series 20kVA 3 Phase Double Conversion Online UPS
Create Energy 20kVA Robust Three Phase Input / Three Phase Output, On-Line Double Conversion UPS
- 20kVA / 16000 Watt / 30 Amps Per Phase
- Internal Batteries
- Software expandable for growth (10kVA - 40kVA)
- Made in RSA for RSA Power Conditions
- Optional Networking and Surge Protection
- Ideal for servers, data-centres etc
*Product Specifications are subject to change without prior notice.
The Create Energy Tower CET3300 Series Double Conversion On-Line UPS Unit is a robust unit manufactured in South Africa for harsh Southern African power conditions.
20kVA CET3320:
- 20kVA / 20000VA / 16000W (16000 Watts) / 30 Amps Per Phase
- Software Size Upgradeable for Growth (If you purchase a 10kVA and your business grows, we can upgrade it to a 15, 20, 30 or 40kVA)
- Efficient Double Conversion ONLINE topology providing the highest reliability, stability, and continous clean power to all critical types of external loads.
- Ideal for Servers, Data-Centres, Critical network devices, Sensitive electronic equipment, Medical, lighting, telecom and industrial uses
- Optional Surge Protection
- Internal Batteries
The CET3300 UPS Range includes the following sizes:
- 10kVA UPS
- 15kVA UPS
- 20kVA UPS
- 30kVA UPS
- 40kVA UPS
The 3300 series of UPSs feature:
- Software expandable for future growth
- Smart tough screen
- Low input harmonic distortion
- Close to unity input power factor
- Digital signal processor charging
- DSP controlled rectifier and inverter
- Built in static switch and Manual bypass
MUST BE INSTALLED BY AN ELECTRICIAN AND UPS SPECIALIST AS PER LOCAL LAWS AND REGULATIONS
EXCLUDES DELIVERY, INSTALLATION AND COMMISSIONING
WARNING DC BUS IS HIGH VOLTAGE: 384VDC
WARRANTIES:
UPS: 1 Year Manufacturer's Carry In Warranty (Owing to normal use)
Batteriess: 6 Months / 200 Cycles / Loadsheddings Manufacturer's Carry In Warranty (Owing to normal use)
Recharge times at C10: 8 - 14 Hours
Batteries being deeply discharged / not being fully charged correctly will shorten the life of batteries / damage batteries which is not covered by the manufacturer's warranty
When runtimes are depleted, the batteries have reached their end of life and will need to be replaced
Run-times of CET3320
Model | Number of Batteries | Encasement | 100% Load Backup Time | 75% Load Backup Time | 50% Load Backup Time |
CET3320-2 | 64 | Internal | 7 Minutes | 12 Minutes | 17 Minutes |
CET3320-3 | 96 | Internal | 13 Minutes |
17 Minutes |
45 Minutes |
CET3320-4 | 128 | Internal | 22 Minutes | 30 Minutes | 45 Minutes |
Data sheet
Nominal Capacity | 20kVA / 16kW |
---|---|
Input Power Factor | 0.98 |
Input Voltage Range | 400VAC +-20% |
Input Frequency Range | 50Hz +- 4% |
Output Voltage Range | 400VAC +- 1% |
Output Frequency | 50Hz +- 0.01Hz (Free Running) |
Output Waveform | Pure Sine Wave |
Rated Output Power Factor | 0.8 |
Output Harmonic Distortion | Less than 2% (Linear Loads) / Less Than 5% (Non Linear Loads) |
Static Switch Rating | 10 Times for 1000ms |
Output Current Crest Ratio | 3:1 |
Battery Technology | AGM (Absobed Glass Mat) Sealed VRLA (Valve Regulated Lead Acid) |
Nominal DC Voltage | 432VDC |
Battery Quantity | 64 Batteries minimum |
Battery Recharge Time | 6 hours to 90% |
Maximum Charge Current | 5A |
Static Bypass | On Overload or UPS Failure |
Manual Bypass | User Operated for Maintenance |
LCD Display | Smart Touch LCD Display with UPS Status, Measurements, Loading, Fault Codes, History and Settings |
Efficiency (Input - Output) | More Than 90% |
Transfer Time | 0ms |
Overload | 200% for 0.01 seconds / 150% for 30 seconds / 125% for 5 minutes |
Alarms | 29 possible alarms for accurate diagnosis |
Communication Dry Contacts (Standard) | Voltage free N/O or N/C Contacts |
Communication RS232 (Optional) | Monitor UPS through Direct Cable Connection and Software |
Communication SNMP (Optional) | Network Control UPS through Management Software and Internet |
Communication GSM (Optional) | Monitor UPS over GSM Network |
Environment Operating Temperature | 0-40 Degrees Celcius |
Environment Operating Humidity | 0-90% Non-Condensing |
Environment Altitude | 0 - 2000m without Derating |
Environment Noise (at 1 meter distance) | 50 - 55dB |
Dimensions UPS (WxDxH) mm | 610 X 890 X 1270 |
Weight (kg) - Excluding Batteries | 240 |