Victron 800VA with DC31 12V 100Ah Deep Cycle Battery 1.2kWh and Battery Cabinet MultiPlus

R12,349.00

Instead of R12,844.63

Tax included
In Stock at Create Energy

Victron MultiPlus 12/800/35-16 230V VE.Bus PLUG AND PLAY DEEP CYCLE KIT

5 Year Manufacturer's warranty on the Inverter / Charger (Owing to normal use)

1 X DC31 12V 100Ah Semi-Sealed, Maintence Free Deep Cycle Battery

800VA / 700W @ 25°C

12VDC, 35A Charger, Lithium Ion battery compatible

Runtimes: 150W for +- 4 Hours

Recharge Time: +- 7 - 11 Hours

16A Transfer Switch

230VAC

Description

Victron MultiPlus 12/800/35-16 230V VE.Bus PLUG AND PLAY DEEP CYCLE KIT

5 Year Manufacturer's warranty on the Inverter / Charger (Owing to normal use)

1 X DC31 12V 100Ah Semi-Sealed, Maintence Free Deep Cycle Battery

800VA / 700W @ 25°C

12VDC, 35A Charger, Lithium Ion battery compatible

Runtimes: 150W for +- 4 Hours

Recharge Time: +- 7 - 11 Hours

16A Transfer Switch

230VAC

Please contact us for quantity discounts

Email: info@createenergy.co.za or telephone: +(27) 11 888 0410

Kit Includes:

1 X Victron MultiPlus 12/800/35-16 230V VE.Bus

1 X Delkor DC31 12V 100Ah Deep Cycle Battery

1 X C2 Steel Battery Cabinet / Trolley on Castor Wheels (Can hold up to 2 X 100Ah 12V Batteries)

1 X Mounted Multiplug outlet

1 X Power inlet cable

Victron Battery On/Off Switch, Mega Fuse Holder, Mega Fuse and 25mm^2 DC Cables

Optional Victron VE.Bus Smart dongle with RJ45 Cable (THIS ALLOWS FOR MONITORING AND CONTROL OF THE INVERTER VIA BLUETOOTH THROUGH THE FREE VICTRONCONNECT APP)

BATTERY

1x Delkor DC31 12V 100Ah Deep Cycle Battery

6 Month / 250 Cycles / Loadsheddings Manufacturers Carry In Warranty (Owing to normal use)

Batteries being deeply discharged / not being fully charged correctly will shorten the life of batteries / damage batteries which is not covered by the manufacturer's warranty

When runtimes are depleted, the batteries have reached their end of life and will need to be replaced

Will run +- 150W of load for +- 4 Hours

Recharge Time: 6 - 10 Hours

RUNTIMES ARE LOAD DEPENDANT

Optional Victron VE.Bus Smart dongle with RJ45 Cable (THIS ALLOWS FOR MONITORING AND CONTROL OF THE INVERTER VIA BLUETOOTH THROUGH THE FREE VICTRONCONNECT APP)

CLICK HERE TO VIEW THE OPTIONAL VE.BUS BLUETOOTH SMART DONGLE ACCESSORY SO YOU CAN MONITOR AND CONTROL YOUR VICTRON PLUG AND PLAY INVERTER / CHARGER VIA THE FREE VICTRONCONNECT BLUETOOTH APP FOR SMARTPHONES / TABLETS:

CLICK HERE FOR THE OPTIONAL VICTRON BLUETOOTH PLUG AND PLAY ADD ON

Screenshots:

     

Victron MultiPlus 12/800/35-16 230V VE.Bus

800VA / 700W @ 25°C

12VDC, 35A Charger

16A Transfer Switch

230VAC

Uninterrupted AC power (UPS function)

In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.

Remote Monitoring and Control

Monitor and control your MultiPlus and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, via the required Color Control GX or Venus GX, from adjusting your MultiPlus to setting a Geofence for hire vehicles and more...

Proven reliability

The full bridge plus toroidal transformer topology has proven its reliability over many years. The inverter is short circuit proof and protected against overheating, whether due to overload or high ambient temperature.

PowerControl - Dealing with limited generator, shore side or grid power

With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.

PowerAssist - Boosting the capacity of shore or generator power

Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.

High start-up power

Needed to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.

Search Mode

When Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.

Programmable relay

By default, the programmable relay is set as an alarm relay, i.e. the relay will de-energise in the event of an alarm or a pre-alarm (inverter almost too hot, ripple on the input almost too high, battery voltage almost too low).

12 Volts

100 A/H

Semi Sealed Maintenance Free

  • Calcium maintenance free dual purpose battery
  • Heavy Duty "Deep Cycle" Wrought lead-calcium grids
  • Low-Resistance envelope separators
  • High strength polypropylene case
  • Heat Sealed covers
  • Exclusive patented liquid gas separator
  • Built in Hygrometer
  • Dual Terminal (SAE Post & 1150K Wing Nut)
  • Ruggedized Heavy Duty Case
  • High CCA Rating

PLEASE NOTE:

The Delkor DC31 is a 12V 100Ah DEEP CYCLE BATTERY

WE RECCOMEND USING THE DC31 (de-coded - Deep Cycle - Group 31 Case Size Marine Deep Cycle Battery) in Domestic Home Inverter Systems!

The Life Expectancy is 250 Cycles from whatever State Of Charge at Beginning of Discharge to 80 % Depth of Discharge!

MANUFACTURER'S WARRANTY IS:

a) 12 Months / 250 Cycles in Marine Vessel or Leisure Vehicle

b) 6 Months / 250 Cycles / Loadsheddings (Whichever comes first) in Load Shedding Inverter Application.

 

DELKOR DC 31 LEAD ACID CALCIUM 100 Ah DEEP CYCLE BATTERY

Delkor Deep Cycle DC31

Batteries built to power up every golf game. Give your golf cart, Trolley Inverter, Trolling Motor and / or Recreational Vehicle   a boost with the Delkor Deep Cycle battery. it keeps them running every day, 

Developed with thicker plates, these enduring lead-acid batteries offer a steadfast amount of current over an extended period of time. Perfect for your recreational golf cart vehicles.


Key Benefits 
  • Convenient maintenance-free battery, no topping up of fluid required
  • Heavy-duty long-lasting design
  • Suitable for most vehicles
  • Resistant to stress from repeated cycling and vibration
  • Anchor-bonding provides increased resistance to vibration
  • Contains more active materials than standard flooded batteries 

SPECS

MODEL: DC31
AH(20HR): 100
RC: 180 Minutes
POST TYPE: SAE and 8 mm Stud 
POLARITY: Centre
LENGTH
DIMENSIONS AND MASS 
LENGTH: 330
WIDTH: 172
HEIGHT: 230
MASS: 27 KG
VOLTAGE:12v
GROUP SIZE: GP31DC (Deep Cycle)

BATTERY LIFE EXPECTATION

The DC31 battery has a 1 year manufacturer’s warranty (carry-in owing to normal use) / 200-250 Cycles @ 80 % Depth of Discharge in Leisure / Marine Use.

The DC31 battery has a 6 month manufacturer’s warranty (carry-in owing to normal use) / 200-250 Cycles / Loadsheddings in Inverter / Standby / UPS Use.

This translates roughly to 200-300 Loadsheddings of 2.5 - 4 Hours Duration (Dependent on load) or 4 - 5 Years Life on Float Charge (Whichever comes first)

Failure to allow sufficient Recharge Time between Loadshedding Events to achieve at least 90 % State of Charge results in ABNORMAL WEAR AND TEAR  due to the battery continuously and repetitively operating in the lower band of State of Charge. An analogy would be operating the Pneumatic Tyres on your car at low pressure (Voltage is "Electrical Pressure")

Fully Discharged Batteries take +- 8 – 16 Hours to fully recharge at the recommended charge rate of 10 % of Capacity. (+-10A Charge on a Wet Cell Calcium Deep Cycle Battery)

We highly recommend that you size your battery accordingly to achieve 4+ hours runtime to Full Discharge (10.5 Volts) Two DC31 Batteries will run 350 Watts of Load for FOUR Hours before reaching the Low State Of Charge Cut Off Voltage.

This results in a Discharge of approximately 50% on a 350 Watt Load after the end of each 2 Hour Loadshedding event, and, at some time during a 24 Hr period, an extended  "rest period" of 10 hours during which the battery can fully Charge to 100 %.

During Eskom Stages 1 - 4 the average loadshedding is 2 hours, this means that the battery will be discharged to +-50% during these Stages 1 - 4, leaving 5 hours charge time (about 50 Ah) to reach "Near Full State of Charge" between Load Shedding events, and, at some time during a 24 Hr period, an extended "rest period" of 10 hours during which the battery can fully Charge to 100 %. (This "Rest Period):

During Periods of Sustained Stage 5 and higher Load Shedding Events we would suggest reducing loads to bare minimum items needed / turning the inverter output off if not in use / Increasing battery capacity to 4 X batteries and charging current to 20A per battery.

NB: THE 1150K BATTERY (and all 102Ah / 105Ah Batteries) ARE NOT "DEEP CYCLE BATTERIES

(1150 K Decoded means 1150 Cranking Amps at Standard Atmospheric Temperature and Pressure)

WE RECCOMEND USING THE DC31 (de-coded - Deep Cycle - Group 31 Case Size Marine Deep Cycle Battery) in Domestic Home Inverter Systems!

Batteries failing due to deep discharges and not being allowed to FULLY recharge between loadsheddings will result in battery failures which are not covered by the manufacturer’s warranty.

Batteries take +- 8 – 16 Hours to fully recharge. (+-10A Charge)

We highly recommend that you size your battery accordingly to make 8 hours runtime
This will mean the battery will be at 50% state of charge at the end of a loadshedding.

We strongly recommend that non-essential items are turned off during loadshedding.

Batteries with reduced runtimes indicate that the battery is reaching / reached it's end of cycle life and should be replaced

General life in standby use during occasional stage 1 - 2 loadshedding: 1 - 3 Years

Design Life: 3 - 5 Years (In standby use, kept on charge, not discharged)

We strongly recommend that non-essential items are turned off during periods of intense loadshedding. Also, Switch off items like the TV set or your computer when sleeping or absent from home, if possible, place the Inverter Charger in "Rest Mode" (Charge, but Do Not Invert) if absent from home or sleeping. Common Sense Prevails!

Batteries with reduced runtimes indicate that the battery is reaching / or is about to reach it's end of cycle life and you should plan a battery replacement

RUNTIMES ON LEAD ACID BATTERIES

Product Details
MP128001XDC31C2
Reviews(0)

Reviews

No customer reviews for the moment.

You need to be logged in or create an account to give your appreciation of a review.

CREATE ENERGY

Your cart

There are no more items in your cart

Sign in