Victron BMV-712 Smart with Panel Indicator, Shunt and Bluetooth App
Victron BMV-712 Smart Dual Battery Monitor with Panel Indicator, Shunt and Bluetooth App
Cable Length: 1.5 m
Cable c.s.a: 3.3 mm2 / 12 AWG
Maximum Current: 20 Amps
(Batteries, Charger, and accessories not included)
Victron BMV-712 Smart Dual Battery Monitor with Panel Indicator, Shunt and Bluetooth App
Bluetooth inside With Bluetooth built-in.
The BMV Smart is ready for the Internet of Things (IoT) era. With Bluetooth being implemented in most other Victron Energy products, wireless communication between products will simplify system installation and enhance performance.
Download the Victron Bluetooth app Use a smartphone or other Bluetooth enabled device to - customize settings, - monitor all important data on single screen, - view historical data, and to - update the software when new features become available.
Easy to install All electrical connections are to the quick connect PCB on the current shunt. The shunt connects to the monitor with a standard RJ12 telephone cable.
Included: RJ 12 cable (10 m) and battery cable with fuse (2 m); no other components needed. Also included are a separate front bezel for a square or round display appearance, a securing ring for rear mounting and screws for front mounting.
Midpoint voltage monitoring One bad cell or one bad battery can destroy a large, expensive battery bank. When batteries are connected in series, a timely warning can be generated by measuring the midpoint voltage. Please see the BMV manual, section 5.2, for more information. We recommend our Battery Balancer (BMS012201000) to maximize service life of series-connected lead-acid batteries.
Very low current draw from the battery Current consumption: 0,7Ah per month (1mA) @12V and 0,6Ah per month (0,8mA) @ 24V Especially Li-ion batteries have virtually no capacity left when discharged until low voltage shutdown. After shutdown due to low cell voltage, the capacity reserve of a Li-ion battery is approximately 1Ah per 100Ah battery capacity. The battery will be damaged if the remaining capacity reserve is drawn from the battery. A residual current of 10mA for example may damage a 200Ah battery if the system is left in discharged state during more than 8 days. Bi-stable alarm relay Prevents increased current draw in case of an alarm.
Other features - Battery voltage, current, power, ampere-hours consumed and state of charge -
Remaining time at the current rate of discharge -
Programmable visual and audible alarm -
Programmable relay, to turn off non critical loads or to run a generator when needed
500 Amp quick connect shunt and connection kit -
Shunt selection capability up to 10.000 Amps -
VE.Direct communication port - Stores a wide range of historical events, which can be used to evaluate usage patterns and battery health -
Wide input voltage range: 6,5 – 70V -
High current measurement resolution: 10 mA (0,01A) -
Additional input to measure voltage (of a second battery), temperature or midpoint voltage, and corresponding alarm and relay settings.
Battery Monitor BMV-712 Smart Supply voltage range 6,5 - 70 VDC
Current draw, back light off < 1mA
Input voltage range, auxiliary battery 6,5 - 70 VDC
Battery capacity (Ah) 1 - 9999 Ah
Operating temperature range -40 +50°C (-40 - 120°F)
Measures voltage of second battery, or temperature, or midpoint Yes
Temperature measurement range -20 +50°C
VE.Direct communication port Yes
Bistable relay 60V / 1A normally open (function can be inverted)
RESOLUTION & ACCURACY (with a 500 A shunt) Current ± 0,01A Voltage ± 0,01V Amp hours ± 0,1 Ah, State of charge (0 – 100%) ± 0,1% Time to go ± 1 min Temperature (0 - 50°C or 30 - 120°F) ± 1°C/°F Accuracy of current measurement ± 0,4% Accuracy of voltage measurement ± 0,3%
INSTALLATION & DIMENSIONS
Installation Flush mount Front 63mm diameter Front bezel 69 x 69mm (2.7 x 2.7 inch) Body diameter and depth 52mm (2.0 inch) and 31mm (1.2 inch)
Protection category IP55 (not intended for outdoor use)
STANDARDS Safety EN 60335-1 Emission / Immunity EN 55014-1 / EN 55014-2 Automotive ECE R10-4 / EN 50498
ACCESSORIES Shunt (included) 500A / 50mV Cables (included) 10 meter 6 core UTP with RJ12 connectors, and cable with fuse for ‘+’ connection Temperature sensor Optional (ASS000100000)
CLICK HERE to Read Product Feature and Specification Brochure
CLICK HERE to read BLOG on Battery Monitor Applications
Download You Software Here:
BMV Reader
(BMV Battery monitor software for models BMV-600 series and 700 series)
https://www.victronenergy.com/support-and-downloads/software#bmv-reader
Victron VRM app
Monitor and manage your Victron Energy system from your phone or tablet. Login with your VRM account, and see all your sites in a list.
(For Android users: If you rare unable to open the apps in the app store? Download the APK files.)
https://www.victronenergy.com/panel-systems-remote-monitoring/bmv-712-smart#software
VictronConnect app
Monitor, configure and update firmware of all Victron products.
Connects to Solar Chargers, Inverters, Inverter/chargers, Battery monitors and more products. All compatible products.
See VictronConnect manual for more information.
https://www.victronenergy.com/support-and-downloads/software#victronconnect-app
Reviews
No customer reviews for the moment.
You need to be logged in or create an account to give your appreciation of a review.