3 X Victron MultiPlus-II 48V 3kVA Inverter / Charger 9kVA Single Phase / 3 Phase Special Bundle
  • On sale!
  • New
  • Pack
3 X Victron MultiPlus-II 48V 3kVA Inverter / Charger 9kVA Single Phase / 3 Phase Special Bundle

3 X Victron MultiPlus-II 48V 3kVA Inverter / Charger 9kVA Single Phase / 3 Phase Special Bundle

R35,499.00
Tax included

VICTRON MULTIPLUS-II 3kVA 48V = 9kVA / 7.2kW Single Phase / 3 Phase

MultiPlus-II 48/3000/35-32 P/N: PMP4882305010 X 3

SPECIAL ONLY VALID UNTIL 31 DECEMBER 2023 / UNTIL STOCK RUNS OUT

Combines the functions of the MuliPlus and MultiGrid

Features of the MultiPlus, + external current transformer option to implement PowerControl & PowerAssist & to optimize self-consumption with external current sensing (max. 32A).
It also has all the features of the MultiGrid with built-in anti-islanding & an increasingly long list of country approvals.

48VDC, 3000VA, 35A Charger, 32A TS

Description

3 X Victron MultiPlus-II 48/3000/35-32 230V

Total of 9kVA / 7200W (7.2kW)

3 Phase system (5kVA / 4kW per Phase) or Single Phase 15kVA / 12kW

3000VA / 2400W @ 25°C

48VDC, 35A Charger X 3 = 105A Charging Power

32A Transfer Switch

It has all the features of the MultiPlus, plus an external current transformer option to implement PowerControl and PowerAssist and to optimize self-consumption with external current sensing (max. 32A). 
It also has all the features of the MultiGrid with built-in anti-islanding and an increasingly long list of country approvals.

 PowerAssist

The MultiPlus-II will prevent overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shore side supply with power taken from the battery.

ESS: Energy Storage Systems

The MultiPlus-II is the key component in a Victron ESS system, providing the flexibility to combine with MPPT Solar Chargers or Grid-tie PV Inverters. For examples and more detailed information see the ESS (Energy Storage System) manual.

Uninterrupted AC power (UPS function)

In the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.

Remote Monitoring and Control

Monitor and control your Multi and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, via the required Color Control GX or Venus GX, from adjusting your Multi to auto starting a back generator and more...

A MultiPlus, plus ESS (Energy Storage System) functionality

The MultiPlus-II is a multifunctional inverter/charger with all the features of the MultiPlus, plus an external current sensor option which extends the PowerControl and PowerAssist function to 50A resp. 100A.
The MultiPlus-II is ideally suited for professional marine, yachting, vehicle and land based off-grid applications.
It also has built-in anti-islanding functionality, and an increasingly long list of country approvals for ESS application.
Several system configurations are possible. For more detailed information see the ESS Design and configuration manual.

PowerControl and PowerAssist - Boosting the capacity of the grid or a generator

A maximum grid or generator current can be set. The MultiPlus-II will then take account of other AC loads and use whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl function).
PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a limited period, the MultiPlus-II will compensate insufficient generator, shore or grid power with power from the battery.

When the load reduces, the spare power is used to recharge the battery.

Solar energy: AC power available even during a grid failure

The MultiPlus-II can be used in off grid as well as grid connected PV and other alternative energy systems. It is compatible with both solar charger controllers and grid-tie inverters.

Two AC Outputs

The main output has no break functionality. The MultiPlus-II takes over the supply to the connected loads in the event of a grid failure or when shore/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.

The second output is live only when AC is available on the input of the MultiPlus-II. Loads that should not discharge the battery, like a water heater for example, can be connected to this output.

Virtually unlimited power thanks to parallel and three phase operation

Up to 6 Multis can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide
25 kW / 30 kVA output power with 420 Amps charging capacity.
In addition to parallel connection, three units of the same model can be configured for three phase output. But that’s not
all: up to 6 sets of three units can be parallel connected for a 75 kW / 90 kVA inverter and more than 1200 Amps charging
capacity.

Remote configuring and monitoring

Install a Color Control GX or other GX product to connect to the internet.
Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge.
When connected to the internet, systems can be accessed remotely, and settings can be changed.

^ Standard marine, mobile or off-grid application

Loads that should shut down when AC input power is not available can be connected to a second output (not shown). These loads will be taken into account by the PowerControl and PowerAssist function in order to limit AC input current to a safe value when AC power is available.

^ Grid parallel topology with MPPT solar charge controller

The MultiPlus-II will use data from the external AC current sensor (must be ordered separately) or power meter to optimise selfconsumption and, if required, to prevent grid feed. In case of a power outage, the MultiPlus-II will continue to supply the critical loads

^ VRM Portal

Our free remote monitoring website (VRM) will display all your system data in a comprehensive graphical format. System settings can be changed remotely via the portal. Alarms can be received by e-mail.

^ VRM app

Monitor and manage yourVictron Energy system from your smart phone and tablet.

Available for both iOS and Android.

^ Connection Area

^ Current sensor 100A:50mA

To implement PowerControl and PowerAssist and to optimize selfconsumption with external current sensing.

Maximum current: 50A resp. 100A.
Length of connection cable: 1 m.

Product Details
PMP482305010X3BUNDLE
Reviews(0)

Reviews

No customer reviews for the moment.

You need to be logged in or create an account to give your appreciation of a review.

CREATE ENERGY

Compare0My Wishlist0

Your cart

There are no more items in your cart

Sign in