CET1100 Series 5kVA Online UPS Single Phase
Create Energy 5kVA Robust, Single Phase Input and Output On-Line UPS
- 5kVA / 3500 Watt / 22 Amps UPS
- Internal Batteries
- Hardwired Unit
- Manufactured in South Africa for Harsh Southern African Power Conditions
- Optional Networking, Wider Voltage Tolerance, Surge Protection
*Product Specifications are subject to change without prior notice.
The Create Energy Tower CET1100 Series On-Line UPS Unit is a robust unit manufactured in South Africa for harsh Southern African power conditions.
5kVA CET1105:
- 5kVA / 5000VA / 3500W (3500 Watts) / 22 Amps
- Optional Special Unit Upgrade: Includes Wider input tolerance and protection against inverter / mains paralleling
- Optional Surge Protection
The CET1100 UPS Range includes the following sizes:
- 3kVA UPS
- 5kVA UPS
- 8kVA UPS
- 10kVA UPS
- 15kVA UPS
- 20kVA UPS
The 1100 series of UPSs feature:
- Efficient Single Conversion reactive ONLINE topology based on PWM design using IGBT power devices.
- As a result, the output remains controlled within 1% with low distortion and noise dissipation, making it ideal for: Servers, Data-centres, Critical network devices, Sensitive electronic equipment, medical, lighting, telecom and industrial uses.
- 20 Character, 2 line Intelligent Diagnostic Display
- Advanced PWM Design
- Single Conversion On-Line
- DC Overcharge Protection
- Aesthetically Pleasing Design
- Unity Power Factor Input
- Long Run-time Battery Capability
- Internal Batteries
- Optional Special Upgrade for CET1100 Series Units provides a wider input voltage window and protection against inverter / mains parralleling
- Optional Fitted Surge Arrestors inside the UPS
MUST BE INSTALLED BY AN ELECTRICIAN AND UPS SPECIALIST AS PER LOCAL LAWS AND REGULATIONS
EXCLUDES DELIVERY, INSTALLATION AND COMMISSIONING
WARNING DC BUS IS HIGH VOLTAGE: 384VDC
WARRANTIES:
UPS: 1 Year Manufacturer's Carry In Warranty (Owing to normal use)
Batteriess: 6 Months / 200 Cycles / Loadsheddings Manufacturer's Carry In Warranty (Owing to normal use)
Recharge times at C10: 8 - 14 Hours
Batteries being deeply discharged / not being fully charged correctly will shorten the life of batteries / damage batteries which is not covered by the manufacturer's warranty
When runtimes are depleted, the batteries have reached their end of life and will need to be replaced
Run-times of CET1105 5kVA
Model | Number of Batteries | Encasement | 100% Load Backup Time | 75% Load Backup Time | 50% Load Backup Time |
CET1105-1 | 32 | Internal, Short Cabinet | 30 Minutes | 37 Minutes | 60 Minutes |
CET1105-2 | 64 | Internal, Tall Cabinet | 65 Minutes | 90 Minutes | 135 Minutes |
CET1105-3 | 96 | Internal, Super Tall Cabinet | 105 Minutes | 135 Minutes | 210 Minutes |
CET1105-4 | 128 | Internal, Super Tall Cabinet | 135 Minutes | 180 Minutes | 300 Minutes |
Data sheet
Nominal Capacity | 5kVA / 3.5kW |
---|---|
Input Power Factor | Up to 0.99 |
Input Voltage Range | 230VAC +-15% (Special Units +- 30%) |
Input Frequency Range | 50Hz +- 5% |
Output Voltage Range | 230VAC +- 1% |
Output Frequency | 50Hz +- 0.05Hz (Free Running) |
Output Waveform | Pure Sine Wave, THD Less Than 5% (no load to full load) - Typically 3% |
Rated Output Power Factor | 0.7 Lagging |
Load Power Factor Range | 0.5 Lagging to Unity within kW Rating of Unit |
Output Harmonic Distortion | Less than 3% THD |
Transient Response | +-5% Under Full Load and Recovery within 30ms |
Static Switch Rating | 1000% for 100ms |
Output Current Crest Ratio | 3:1 |
Synchronization | Slew Rate: 1Hz/s |
Battery Technology | AGM (Absobed Glass Mat) Sealed VRLA (Valve Regulated Lead Acid) |
Nominal DC Voltage | 432VDC |
Battery Quantity | 32 Batteries Minimum |
Battery Recharge Time | 6 hours to 90% |
Maximum Charge Current | 3A (adjustable higher, load dependent) |
Static Bypass | On Overload or UPS Failure |
Manual Bypass | User Operated for Maintenance |
LCD Display | UPS Status, Measurements, Loading, Fault Codes |
Efficiency (Input - Output) | More Than 95% |
Transfer Time | 0ms |
Overload | 200% for 15 seconds. Short Circuit Capability without Damage |
Alarms | 27 Possible alarms for accurate diagnosis |
Communication Dry Contacts (Standard) | Voltage free N/O or N/C Contacts |
Communication RS232 (Optional) | Monitor UPS through Direct Cable Connection and Software |
Communication SNMP (Optional) | Network Control UPS through Management Software and Internet |
Communication GSM (Optional) | Monitor UPS over GSM Network |
Environment Operating Temperature | 0-40 Degrees Celcius |
Environment Operating Humidity | 0-90% Non-Condensing |
Environment Altitude | 0 - 2000m without Derating |
Environment Noise (at 1 meter distance) | Less than 50dB |
Dimensions Shot Cabinet UPS (WxDxH) mm | 370 X 680 X 600 |
Dimensions Tall Cabinet UPS (WxDxH) mm | 370 X 680 X 845 |
Dimensions Super Tall Cabinet UPS (WxDxH) mm | 370 X 680 X 1320 |
Weight (kg) - Excluding Batteries Short Cabinet | 50 |
Weight (kg) - Excluding Batteries Tall Cabinet | 63 |
Weight (kg) - Excluding Batteries Super Tall Cabinet | 89 |