Create Energy CET1105 5kVA Robust Online UPS System
  • Online only
  • New
Create Energy CET1105 5kVA Robust Online UPS System

CET1100 Series 5kVA Online UPS Single Phase

R42,999.00
Tax included

Create Energy 5kVA Robust, Single Phase Input and Output On-Line UPS

  • 5kVA / 3500 Watt / 22 Amps UPS
  • Internal Batteries
  • Hardwired Unit
  • Manufactured in South Africa for Harsh Southern African Power Conditions
  • Optional Networking, Wider Voltage Tolerance, Surge Protection

Run Time Options at FULL Load. (Refer to chart at the bottom)

Custom Built Unit: 6 - 10 Working Weeks Lead Time
Description

*Product Specifications are subject to change without prior notice.

The Create Energy Tower CET1100 Series On-Line UPS Unit is a robust unit manufactured in South Africa for harsh Southern African power conditions.

5kVA CET1105:

  • 5kVA / 5000VA / 3500W (3500 Watts) / 22 Amps
  • Optional Special Unit Upgrade: Includes Wider input tolerance and protection against inverter / mains paralleling
  • Optional Surge Protection

The CET1100 UPS Range includes the following sizes:

  • 3kVA UPS
  • 5kVA UPS
  • 8kVA UPS
  • 10kVA UPS
  • 15kVA UPS
  • 20kVA UPS

The 1100 series of UPSs feature:

  • Efficient Single Conversion reactive ONLINE topology based on PWM design using IGBT power devices.
  • As a result, the output remains controlled within 1% with low distortion and noise dissipation, making it ideal for: Servers, Data-centres, Critical network devices, Sensitive electronic equipment, medical, lighting, telecom and industrial uses.
  • 20 Character, 2 line Intelligent Diagnostic Display
  • Advanced PWM Design
  • Single Conversion On-Line
  • DC Overcharge Protection
  • Aesthetically Pleasing Design
  • Unity Power Factor Input
  • Long Run-time Battery Capability
  • Internal Batteries
  • Optional Special Upgrade for CET1100 Series Units provides a wider input voltage window and protection against inverter / mains parralleling
  • Optional Fitted Surge Arrestors inside the UPS

MUST BE INSTALLED BY AN ELECTRICIAN AND UPS SPECIALIST AS PER LOCAL LAWS AND REGULATIONS

EXCLUDES DELIVERY, INSTALLATION AND COMMISSIONING

WARNING DC BUS IS HIGH VOLTAGE: 384VDC

WARRANTIES:

UPS: 1 Year Manufacturer's Carry In Warranty (Owing to normal use)

Batteriess: 6 Months / 200 Cycles / Loadsheddings Manufacturer's Carry In Warranty (Owing to normal use)
Recharge times at C10: 8 - 14 Hours
Batteries being deeply discharged / not being fully charged correctly will shorten the life of batteries / damage batteries which is not covered by the manufacturer's warranty
When runtimes are depleted, the batteries have reached their end of life and will need to be replaced

Run-times of CET1105 5kVA

Model Number of Batteries Encasement 100% Load Backup Time 75% Load Backup Time 50% Load Backup Time
CET1105-1 32 Internal, Short Cabinet 30 Minutes 37 Minutes 60 Minutes
CET1105-2 64 Internal, Tall Cabinet 65 Minutes 90 Minutes 135 Minutes
CET1105-3 96 Internal, Super Tall Cabinet 105 Minutes 135 Minutes 210 Minutes
CET1105-4 128 Internal, Super Tall Cabinet 135 Minutes 180 Minutes 300 Minutes
Product Details
CET1105-1

Data sheet

Nominal Capacity5kVA / 3.5kW
Input Power FactorUp to 0.99
Input Voltage Range230VAC +-15% (Special Units +- 30%)
Input Frequency Range50Hz +- 5%
Output Voltage Range230VAC +- 1%
Output Frequency50Hz +- 0.05Hz (Free Running)
Output WaveformPure Sine Wave, THD Less Than 5% (no load to full load) - Typically 3%
Rated Output Power Factor0.7 Lagging
Load Power Factor Range0.5 Lagging to Unity within kW Rating of Unit
Output Harmonic DistortionLess than 3% THD
Transient Response+-5% Under Full Load and Recovery within 30ms
Static Switch Rating1000% for 100ms
Output Current Crest Ratio3:1
SynchronizationSlew Rate: 1Hz/s
Battery TechnologyAGM (Absobed Glass Mat) Sealed VRLA (Valve Regulated Lead Acid)
Nominal DC Voltage432VDC
Battery Quantity32 Batteries Minimum
Battery Recharge Time6 hours to 90%
Maximum Charge Current3A (adjustable higher, load dependent)
Static BypassOn Overload or UPS Failure
Manual BypassUser Operated for Maintenance
LCD DisplayUPS Status, Measurements, Loading, Fault Codes
Efficiency (Input - Output)More Than 95%
Transfer Time0ms
Overload200% for 15 seconds. Short Circuit Capability without Damage
Alarms27 Possible alarms for accurate diagnosis
Communication Dry Contacts (Standard)Voltage free N/O or N/C Contacts
Communication RS232 (Optional)Monitor UPS through Direct Cable Connection and Software
Communication SNMP (Optional)Network Control UPS through Management Software and Internet
Communication GSM (Optional)Monitor UPS over GSM Network
Environment Operating Temperature0-40 Degrees Celcius
Environment Operating Humidity0-90% Non-Condensing
Environment Altitude0 - 2000m without Derating
Environment Noise (at 1 meter distance)Less than 50dB
Dimensions Shot Cabinet UPS (WxDxH) mm370 X 680 X 600
Dimensions Tall Cabinet UPS (WxDxH) mm370 X 680 X 845
Dimensions Super Tall Cabinet UPS (WxDxH) mm370 X 680 X 1320
Weight (kg) - Excluding Batteries Short Cabinet50
Weight (kg) - Excluding Batteries Tall Cabinet63
Weight (kg) - Excluding Batteries Super Tall Cabinet89