Victron Phoenix Smart IP43 Charger 24/25(1+1) 230V PSC242551085
Victron Phoenix Smart IP43 Charger 24/25(1+1) 230V PSC242551085
  • -33.01%
  • New
Victron Phoenix Smart IP43 Charger 24/25(1+1) 230V PSC242551085
Victron Phoenix Smart IP43 Charger 24/25(1+1) 230V PSC242551085

Victron Phoenix Smart IP43 Charger 24/25(1+1) 230V

R10,010.75 R6,706.20
Tax included

Victron Phoenix Smart IP43 Charger 24/25(1+1) 230V

</ = 25 A Main House Battery Charger Plus </= 3 A Battery Maintainer for 24 V Primary Cranking Battery

Wide AC Input Range 120-240 Vac

Adjustable DC Output Current Setting

Ready for Parallel and Redundant Operation

Natural Convection Cooling

Adaptive 5 Stage Charge Algorithm

Less than 1 mA Self Consumption

Full Rated Output up to 40 Deg C

IP43 Degree of Ingress Protection

Requires CE 13 "Kettle" Plug - Not Included

Description

Victron Phoenix Smart IP43 Charger 24/25(1+1) 230V

</ = 25 A Main House Battery Charger Plus </= 3 A Battery Maintainer for 24 V Primary Cranking Battery

Wide AC Input Range 120-240 Vac

Adjustable DC Output Current Setting

Ready for Parallel and Redundant Operation

Natural Convection Cooling

Adaptive 5 Stage Charge Algorithm

Less than 1 mA Self Consumption

Full Rated Output up to 40 Deg C

IP43 Degree of Ingress Protection

Requires CE 13 "Kettle" Plug - Not Included

Multiple battery outputs

The 1+1 and 3 output version chargers both have an integrated FET battery isolator and therefore feature separate isolated outputs.

With 1+1 output models, the main output can supply the full rated current and the starter/auxiliary output is limited to a maximum of 4A; however the combined current of all outputs is limited to the full rated current.

With the 3 output models, all 3 outputs can supply the full rated output current; however the combined current of all outputs is limited to the full rated output current.

Multiple isolated outputs make it possible for a single charger to charge multiple batteries, while keeping the batteries isolated from each other.

With boat owners in mind this adaptive 5-step charger can provide either 25 A of charge to a Main 24 V battery bank, or, this Phoenix 1+1 model provides 3A to the starter-battery, the rest to the ‘house’ bank. 12 V models are also available with 30A/50A charge. Bluetooth enabled, you can monitor the charger and set alarms straight from your phone. Adaptive, intelligent, dynamic charge features – see the datasheet below. 

Features (Refer to Downloadable Manual)

  1. Bluetooth setup and monitoring (Using VictronConnect)

    Equipped with integrated Bluetooth; enabling quick and simple setup, advanced configuration, comprehensive monitoring and firmware updates via the VictronConnect app and a Bluetooth enabled device (such as a mobile phone or tablet).

  2. VE.Smart Network compatible

    VE.Smart Networking capability allows multiple chargers to operate in unison with synchronised charging, and receive accurate battery voltage (Voltsense), charge current (Current-sense) and battery temperature (Temp-sense) data from a compatible battery monitor (such as a BMV, SmartShunt, Smart Battery Sense or VE.Bus Smart Dongle) to further enhance the charge cycle.

  3. VE.Direct interface

    Fully integrate with a GX device (such as a Cerbo GX) via VE.Direct interface, enabling system monitoring and control from a single device and connectivity to the VRM (Victron Remote Monitoring) portal for data logging and remote access to real time monitoring, as well as control of the charger.

  4. Integrated charge presets

    Integrated charge presets (selected via the MODE button or VictronConnect app) combined with adaptive charge logic are well suited for most common battery types; such as LiFePO4, AGM, Gel and flooded lead-acid. Advanced configuration with specific user defined settings is also possible using VictronConnect.

  5. Multi-stage charge algorithm

    The multi-stage charge algorithm is specifically engineered to optimise each recharge cycle and charge maintenance over extended periods.

  6. Adaptive absorption

    Adaptive absorption monitors the battery’s response during initial charging and intelligently determines the appropriate absorption duration for each individual charge cycle. This ensures that the battery is fully recharged regardless of the discharge level or capacity and avoids excessive time at the elevated absorption voltage (that can accelerate battery aging).

  7. Temperature compensation

    Charge voltage is automatically compensated depending on the ambient temperature; this ensures that the battery is charged at the optimal charge voltage regardless of the climate and avoids the need for manual settings adjustments. Temperature compensation is not required and automatically disabled when in LI-ION charge mode.

  8. High efficiency

    The Phoenix Smart IP43 Charger range is up to ~96% efficient; resulting in lower power usage, less heat generated and cooler operation

  9. Durable and safe

    1. Engineered to provide years of trouble-free and dependable operation in all usage conditions

    2. Protection against overheating: output current will be reduced if the charger temperature increases above 40°C (linear derate from 100% at 40°C to 20% at 60°C)

    3. Protection against output short circuit

    4. Protection against reverse polarity connection (internal fuse - not replaceable)

  10. Silent operation

    Totally silent operation since there is no cooling fan or moving parts, cooling is via natural convection; full rated output current is still provided up to an ambient temperature of 40°C.

  11. Lithium Ion compatible

    Compatible with Li-ion (LiFePO₄) batteries; when the integrated LI-ION charge mode is selected the charge cycle settings are altered to suit.

    If the charger is connected to a battery where under voltage protection (UVP) has tripped, the Phoenix Smart IP43 Charger range will automatically reset UVP and start charging; many other chargers will not recognise a battery in this state.

    Warning: Do not charge Li-ion batteries if the battery temperature is below 0°C.

  12. Storage stage

    An additional stage to extend battery life whilst the battery is unused and on continuous charge.

  13. Recondition stage

    An optional stage that can partially recover/reverse lead acid battery degradation due to sulfation; typically caused by inadequate charging or if the battery is left in a deeply discharged state.

  14. Configurable output current

    A configurable setting that limits the maximum charge current to a reduced level; beneficial when charging lower capacity batteries with a high current charger.

  15. Recovery function

    The Phoenix Smart IP43 Charger range will attempt to recharge a severely discharged battery (even down to 0V) with low current and then resume normal charging once the battery voltage has risen sufficiently - many other chargers will not recognise a battery in this state.

  16. Power supply mode

    A specific mode to use the charger as a DC power supply; to power equipment at a constant voltage with or without a battery connected.

  17. The 1+1 and 3 output version chargers both have an integrated FET battery isolator and therefore feature seperate isolated outputs.

    With 1+1 output models, the main output can supply the full rated current and the starter/auxiliary output is limited to a maximum of 4A; however the combined current of all outputs is limited to the full rated current.

    With the 3 output models, all 3 outputs can supply the full rated output current; however the combined current of all outputs is limited to the full rated output current.

    Multiple isolated outputs make it possible for a single charger to charge multiple batteries, while keeping the batteries isolated from each other.

Phoenix Smart IP43

Product Details
PSC242551085
Reviews(0)

Reviews

No customer reviews for the moment.

You need to be logged in or create an account to give your appreciation of a review.

CREATE ENERGY

Compare0My Wishlist0

Your cart

There are no more items in your cart

Sign in