Lowrance Ghost 24 V / 36 V Trolling Motor
24 / 36 V
47 / 52 / 60 inch Shaft Options
ADD THE LOWRANCE ACTIVE IMAGING 3-IN-1 NOSECONE TO ACTIVATE THE GHOST 360 SCANNING FEATURE!
Victron smallBMS
A simple and low cost alternative to the VE.Bus BMS V2
The smallBMS can replace the VE.Bus BMS V2 in several applications. It is however not suitable for use with VE.Bus MultiPlus and Quattro inverter/chargers: it has no VE.Bus interface. The smallBMS is intended for use with Victron Smart LiFePo4 batteries with M8 circular connectors.
The smallBMS has two outputs, similar to the VE.Bus BMS V2.
Victron VE.Bus BMS V2
The VE.Bus BMS V2 is a Battery Management System (BMS) designed to interface with and protect a single, or multiple Victron Lithium Battery Smart 12,8V & 25,6V (LiFePO4 or LFP) in systems that have Victron inverters or inverter/chargers with VE.Bus communication. It monitors and protects the batteries against over voltage and under voltage of any individual cell, and also over temperature or under temperature conditions.
Based on the status of the battery or batteries, the BMS will:
- Generate a pre-alarm signal to alert of an imminent cell under voltage condition.
- Disable inverting in VE.Bus inverters or inverter/chargers via VE.Bus, and disable other loads via the 'Load Disconnect' terminal in the event of a cell under voltage condition.
- Disable charging in VE.Bus inverters or inverter/chargers via VE.Bus and disable other chargers via the 'Charge Disconnect' terminal in the event of a cell overvoltage, under temperature or over temperature condition.
- Remote on/off terminals.
- Ability to disable VE.Direct and VE.Can solar chargers via a GX device.
- Allowing control of the VE.Bus inverter/charger from multiple devices, like the Digital Multi Control, the VE.Bus Smart dongle and/or a GX device.
- Auxiliary power input and output terminals that allow a GX device to remain powered in the event of a system shutdown.
Victron VE.Bus BMS
The VE.Bus BMS is a Battery Management System (BMS) designed to interface with and protect a single, or multiple Victron Lithium Battery Smart 12,8V & 25,6V (LiFePO4 or LFP) in systems that have Victron inverters or inverter/chargers with VE.Bus communication. It monitors and protects the batteries against over voltage and under voltage of any individual cell, and also over temperature or under temperature conditions.
Based on the status of the battery or batteries, the BMS will:
- Generate a pre-alarm signal to alert of an imminent cell under voltage condition.
- Disable inverting in VE.Bus inverters or inverter/chargers via VE.Bus, and disable other loads via the 'Load Disconnect' terminal in the event of a cell under voltage condition.
- Disable charging in VE.Bus inverters or inverter/chargers via VE.Bus and disable other chargers via the 'Charge Disconnect' terminal in the event of a cell overvoltage, under temperature or over temperature condition.
- Remote on/off terminals.
- Ability to disable VE.Direct and VE.Can solar chargers via a GX device.
- Allowing control of the VE.Bus inverter/charger from multiple devices, like the Digital Multi Control, the VE.Bus Smart dongle and/or a GX device.
- Auxiliary power input and output terminals that allow a GX device to remain powered in the event of a system shutdown.
Victron Phoenix Phoenix Smart IP43 Charger 24/16(1+1) 230V
</ = 16 A Main House Battery Charger Plus </= 4 A Battery Maintainer for 24 V Primary Cranking Battery
Wide AC Input Range 120-240 Vac
Adjustable DC Output Current Setting
Ready for Parallel and Redundant Operation
Natural Convection Cooling
Adaptive 5 Stage Charge Algorithm
Less than 1 mA Self Consumption
Full Rated Output up to 40 Deg C
IP43 Degree of Ingress Protection
Requires CE 13 "Kettle" Plug - Not Included
Victron Phoenix IP43 Smart Charger 12 V / 50 A (1+1) 230V
</ = 50 A Main House Battery Charger Plus </= 4 A Battery Maintainer for Primary Cranking Battery
Wide AC Input Range 120-240 Vac
Adjustable DC Output Current Setting
Ready for Parallel and Redundant Operation
Natural Convection Cooling
Adaptive 5 Stage Charge Algorithm
Less than 1 mA Self Consumption
Full Rated Output up to 40 Deg C
IP43 Degree of Ingress Protection
Requires CE 13 "Kettle" Plug - Not Included
Victron Phoenix IP43 Smart Charger 12 V / 30 A (1+1) 230V
</ = 30 A Main House Battery Charger Plus </= 4 A Battery Maintainer for Primary Cranking Battery
Wide AC Input Range 120-240 Vac
Adjustable DC Output Current Setting
Ready for Parallel and Redundant Operation
Natural Convection Cooling
Adaptive 5 Stage Charge Algorithm
Less than 1 mA Self Consumption
Full Rated Output up to 40 Deg C
IP43 Degree of Ingress Protection
Requires CE 13 "Kettle" Plug - Not Included
Victron Phoenix Smart IP43 Charger 24/25(3) 120-240V
Wide AC Input Range 120-240 Vac
Adjustable DC Output Current Setting
Ready for Parallel and Redundant Operation
Natural Convection Cooling
Adaptive 5 Stage Charge Algorithm
Less than 1 mA Self Consumption
Full Rated Output up to 40 Deg C
IP43 Degree of Ingress Protection
Requires CE 13 "Kettle" Plug - Not Included
Victron Phoenix Smart IP43 Charger 12/50(3) 120-240V
Wide AC Input Range 120-240 Vac
Adjustable DC Output Current Setting
Ready for Parallel and Redundant Operation
Natural Convection Cooling
Adaptive 5 Stage Charge Algorithm
Less than 1 mA Self Consumption
Full Rated Output up to 40 Deg C
IP43 Degree of Ingress Protection
Requires CE 13 "Kettle" Plug - Not Included
Victron Cyrix-i 24/48V-400A intelligent battery combiner
Victron Cyrix-i 12/24V-400A intelligent battery combiner
Victron Cyrix-ct 12/24V-230A intelligent battery combiner
Victron Cyrix-ct 12/24V-120A intelligent battery combiner
Victron Phoenix Inverter 12/1200 230V VE.Direct IEC
Inverter
Victron Inverter RS 48/6000 230V Smart
The Inverter RS Smart is a powerful 48 VDC, 6 kVA 230 VAC inverter. It features a modern design and high frequency technology, weighing only 11kg and has excellent efficiency, low standby power, and very quiet operation.
The inverter is equipped with a display to read out battery and inverter details. These parameters can also be read out via Bluetooth by the VictronConnect app. In addition to this, the inverter has a VE.Can Port, for connection to a GX device for system monitoring.